GENERATOR OUTPUTS: modulated output:
unbalanced sine carrier, 1 kHz
3V
pp
(MARK), 1V
pp
(SPACE) into 50 Ω
unmodulated outputs (DCLS):
TTL into 50 Ω
RS-422
active high or low selectable by jumper
optical output (option):
optical power: typ. 15µW
optical connector: ST-connector
for GI 50/125µm
or GI 62,5/125µm
gradient fiber
PULSE OUTPUTS: three programmable outputs, TTL level
Default settings:
active only ‚if sync‘
PPO0: change of second (PPS)
pulse duration 200 msec
valid on rising edge
PPO1: change of minute (PPM)
pulse duration 200 msec
valid on rising edge
PPO2: DCF77 simulation
SERIAL PORT: configurable RS-232 interface
baudrates: 300 Bd...38400 Bd
framing: 7E2, 8N1, 8N2, 8E1
mode of operation: string per second
string per minute
string on request
time telegram: Meinberg Standard,
Uni Erlangen, SAT,
Capture Telegram
CAPTURE INPUTS: triggered by falling TTL slope
pulse repetition time: 1.5 msec min.
resolution: 800 nsec
output of trigger event via PCI-bus or serial
interface