Description of IRIG-Codes
The specification of individual IRIG time code formats is defined in IRIG Standard
200-98. They are described by an alphabetical character followed by a three-digit
number sequence. The following identification is taken from the IRIG Standard 200-
98 (only the codes relevant to TCR170PEX are listed):
character bit rate designation A 1000 pps
B 100 pps
1st digit form designation 0 DC Level Shift
width coded
1 sine wave carrier
amplitude modulated
2nd digit carrier resolution 0 no carrier (DC Level Shift)
1 100 Hz, 10 msec resolution
2 1 kHz, 1 msec resolution
3 10 kHz, 100 μsec resolution
3rd digit coded expressions 0 BCD, CF, SBS
1 BCD, CF
2 BCD
3 BCD, SBS
BCD: time of year, BCD-coded
CF: Control-Functions (user defined)
SBS: seconds of day since midnight (binary)